Abstract

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here presented significantly reduces the dependence between the detector area and the number of electronic channels, without substantial reduction of its performance: a 30 × 30 cm2 double stack multi-gap timing RPC was operated during weeks with cosmic rays, achieving a 2D spatial resolution well below 1 mm and time resolution lower than 100 ps, while its efficiency was kept above 98%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.