Abstract

The New Preloaded System (NPS) for renal/visceral arteries (TVVs) is an emerging technology in fenestrated endografting (FEVAR) that allows TVVs cannulation and stenting through the same access of the endograft main body. However, only few preliminary experiences are currently available in the literature. The aim of this study is to report the outcomes of NPS-FEVAR in juxta/para-renal (J/P-AAAs) and thoracoabdominal (TAAAs) aneurysms repair. This is a prospective (NCT05224219), single-center/observational study of patients submitted to NPS-FEVAR for J/PAAAs and TAAAs between 2019 and 2022 (July). Definitions and outcomes were evaluated according to the current SVS-reporting standard. Technical success (TS) and TS preloaded related, spinal cord ischemia (SCI), and 30-day mortality were assessed as early endpoints. Survival, freedom from reinterventions (FFRs), and freedom from TTVs-instability (FFTVVs-instability) were analyzed during follow-up. Among 157 F/B-EVAR cases, 74 (47%) NPS-FEVAR were planned and enrolled in the study [48 (65%) J/P-AAAs; 26 (35%) TAAAs]. The main indication for NPS-FEVAR was the presence of a hostile iliac axis (54%-73%) or the necessity of expeditious pelvic/lower-limb reperfusion for SCI prevention in TAAAs (20%-27%). Overall, 292 TVVs were accommodated by 289 fenestrations and 3 branches; 188 of 289 (65%) fenestrations were preloaded. NPS-FEVAR configuration was from "below" and "from below to above" in 28 (38%) and 46 (62%) cases, respectively. TS and TS preloaded system-related was 96% (71/74) and 99% (73/74), respectively. Target visceral vessels patency at the completion angiography was 99% (290/292). Failures were 2 renal arteries loss and 1 massive bleeding from a percutaneous closure system breakage. The latter patient developed postoperative multiorgans failure and died on the fifth postoperative day, causing only 30-day/in-hospital mortality (1.3%). One (1.3%) patient with a JAAA and preoperative bilateral occlusion of the hypogastric arteries suffered SCI. The median follow-up was 14 (IQR: 8) months. The estimated 3-year survival was 91% with no aneurysm-related mortality during follow-up. The estimated 3-year FFR and FFTVVs-instability were 85 and 92%, respectively. New preloaded system FEVAR is a safe and effective option in the treatment of J/PAAAs and TAAAs in the presence of hostile iliac access or to guarantee an expeditious pelvic/lower limb reperfusion, leading to satisfactory results in terms of TS, early and mid-term clinical outcomes. New preloaded system for fenestrated and branched endografting allows to increase the feasibility of the advanced endovascular aortic repair in challenging iliac access, thoracoabdominal aneurysm repair and reduce difficulties in target visceral vessels cannulation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.