The mathematical description and the computer program Devil Erosion of calculation the two-dimensional temperature fields in any vertical and horizontal section of the blast furnace hearth are developed. Calculation is carry out the decision of the equations of heat conductivity with use of indications of the big number of sensing transducers of temperature (to 1000), built in the furnaces firebrick lining between the firebrick blocks. The continuous control of the temperature change in each point allows to define the remained thickness the firebrick lining and to warn, in case of need, the furnace personnel about the beginning of the firebrick lining erosion. The continuous control of change of temperature in the firebrick lining is made on the basis of mathematical model. The system of collecting, processing and transfer information from sensing transducers of temperature or thermal streams in a program database Devil Erosion is used. Programs are installed on blast furnaces of Chinese National Republic: Jinan, Jiyuan and Liuzhou Iron and Steel Works.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.