Abstract
ABSTRACTNMR spectroscopy is used to determine fat content and internal temperature of hamburger, pork sausage, and various cuts of chicken during cooking. The temperature is determined by the frequency difference of the water and fat lines within the NMR spectrum. This method is more accurate than the absolute measurement of either peak alone. Furthermore, because the measurement relies on a frequency difference, precise control of the magnetic field is unnecessary. The hamburger and sausage data indicate an accuracy of ± 1C. The temperature accuracy for chicken is ± 5C. The difference in accuracy is due to the lower fat content of chicken. Chicken bone marrow, however, has a high fat content which could be used to measure its temperature. The speed and accuracy of this technique admits the possibility of using NMR spectroscopy on the process line to determine when these cuts of meat are sufficiently cooked and thus safe.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.