Abstract
In this paper, a new mathematical approach for calculation of Eddy Current Losses in Air-Gap-Windings is introduced. Based on magnetic field simulations in ANSYS Maxwell of the PMSM, developed at Otto-von-Guericke-University Magdeburg, the magnetic flux through the winding is estimated. The calculation of the losses is realized by using differential small conductor loops representing the flow of the eddy current inside the copper windings. The approach is validated and compared with measured eddy current loss from two different PMSM with Air-Gap-Winding.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.