Abstract

This paper describes a novel method to measure straightness error of an axis of motion with a system utilising taut wire, optical sensor and reference error cancellation technique. In contrast to commonly used taut wire, straightedge or laser-based methods it combines simplicity of setup and low cost with high levels of automation, accuracy and repeatability. An error cancellation technique based on two-point method is applied for the first time to a versatile reference object which can be mounted at any place of machine's working volume allowing direct measurement of motion straightness of a tool point. Experimental results on a typical machine tool validate performance of the proposed taut wire system with a commercial laser interferometer operating in the same conditions is used as a reference. The proposed method shows highly repeatable results of better than ±0.25μm over the range of 0.48m and measurement accuracy comparable to the interferometer of ±0.5μm.

Highlights

Read more

Summary

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.