Abstract

This paper presents a new detection technique of initial position for a three-phase brushless DC motor which does not require any current and position sensors, and thereby significantly reduces the cost. The fundamental principle of the technique is to determine the initial position of the permanent magnet by the time periods of discharge of stator windings, which are excited before discharge. As compared to previous approaches, the presented technique does not cause any rotation during detection, and it is therefore very promising for particular kinds of applications, which do not allow the motor to rotate potentially in the wrong direction during initial position detection, e.g., electrical vehicles. As compared to earlier techniques, the presented technique dramatically simplifies the detection procedures and cost. Experimental results derived from a field-programmable gate-array-based control system are presented to demonstrate the feasibility of the presented technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.