Abstract

Background-Aim: The technique of abdominal closure along with the material to be used is constantly evolving. The aim of the present study is to evaluate differences in midline laparotomy closure with a standard closure technique and new-fangled slow-absorbable versus non-absorbable sutures. Material and Methods: A prospective, comparative study of patients undergoing laparotomy closure with either STARDIOX (Polydioxanone) or STARLENE (Polypropylene) sutures during a 9 month period was performed. Patients were evaluated and compared in terms of surgical site infection, incisional hernia, burst abdomen, and suture sinus formation. Results: A total of 284 patients were included [141 in the STARDIOX (Polydioxanone) group and 143 in the STARLENE (Polypropylene) group]. Sinus formation was not noticed and no palpable knots were reported in both groups. Moreover burst abdomen was never encountered. Incisional hernia rates were similar for both suture materials: n = 6 (4.3%) for the STARDIOX (Polydioxanone) group and n = 5 (3.5%) for the STARLENE (Polypropylene) group. There was not statistically significant relationship between the type of suture that was used and wound infection: n = 5 (3.5%) in the STARDIOX (Polydioxanone) group and n = 6 (4.2%) in the STARLENE (Polypropylene) group. Complications did not occur in 96.1% of all patients. Conclusions: Our study suggests that there are no significant differences between these two new-fangled sutures. It seems that progress of suture materials has led to a step towards the goals of a beneficial suture and from then on complications of surgical wound closure should be merely a matter of operative technique.

Highlights

  • Complications of surgical wound closure significantly increase morbidity and mortality

  • Incisional hernia rates were similar for both suture materials: n = 6 (4.3%) for the STARDIOX (Polydioxanone) group and n = 5 (3.5%) for the STARLENE (Polypropylene) group

  • As the main objective of the present study was to evaluate patients undergoing laparotomy closure with either STARDIOX (Polydioxanone) or STARLENE (Polypropylene) sutures, data were tabulated comparing between these two groups of patients in terms of surgical site infection, incisional hernia, burst abdomen, and suture sinus formation

Read more

Summary

Introduction

Complications of surgical wound closure significantly increase morbidity and mortality. Material and Methods: A prospective, comparative study of patients undergoing laparotomy closure with either STARDIOX (Polydioxanone) or STARLENE (Polypropylene) sutures during a 9 month period was performed. Patients were evaluated and compared in terms of surgical site infection, incisional hernia, burst abdomen, and suture sinus formation. Incisional hernia rates were similar for both suture materials: n = 6 (4.3%) for the STARDIOX (Polydioxanone) group and n = 5 (3.5%) for the STARLENE (Polypropylene) group. Conclusions: Our study suggests that there are no significant differences between these two new-fangled sutures It seems that progress of suture materials has led to a step towards the goals of a beneficial suture and from on complications of surgical wound closure should be merely a matter of operative technique

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call