Abstract
Integrated three-phase AC-DC system is widely used in modern society with series of base units. In this paper we deduce a general equation of the system in an affine coordination in order to use the differential geometry. Firstly, a new approximate equivalence method is presented by differential homology, including the judgment criterion and the main parameters of the equivalent model. Besides, the chaotic analysis relates different parameters to different situations which can accurately be simulated by PSCAD/EMTDC. And then calculation of eigenvalue indicates that the equivalence method is useful and simple. Finally, a simulation shows the accuracy and the applicability of the method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.