Abstract

In this study, a new test method was proposed to evaluate the shear-induced volumetric changes, namely Reynolds dilatancy (RD), of sixteen conventional vibrated concrete (CVC) mixtures under free-surface flow. The RD measurements were carried out using a rheometer set-up and different vane-blade types rotating at different speeds. According to the experimental results, the RD values were found in good agreement with the workability of the investigated mixtures. Moreover, the RD values were well correlated with the coupled effect of the relative solid packing fraction of coarse aggregate (φ/φmax) and viscoplastic properties of the investigated CVC mixtures. Furthermore, a strong correlation was established between the rheological properties of the lubrication layer, RD values, and the φ/φmax of coarse aggregate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.