Abstract

Although there are many methods and instruments for measuring viscosity, it is still difficult to determine a reliable value of the dynamic viscosity of complex chemicals such as paraffins and fatty acids. This is due to the complex and heterogeneous structure of these compounds in the case of commercial products. On the other hand, the measuring instrument should be selected very carefully, including its measuring principle and measuring range. This paper presents results of viscosity measurements of three organic PCMs (phase change materials) obtained in four different research institutions. Commercial products: paraffin, myristic acid (97%) and mixture of palmitic acid (55%) and stearic acid (45%) were selected as PCMs. Four different viscometers, namely Fungilab V-Pad, Rheotest LK 2.2, Rheometer Anton Paar MCR 102, and Brookfield DV-II + Pro have been used to determine temperature dependent dynamic viscosity of the tested PCMs. Using a large database of present measurement results, correlations were developed to calculate the dynamic viscosity of fatty acids and paraffins, which predict the experimental data within a band of ±20%.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call