Abstract

The present article introduces a new approach to fabricate carbon paste sensors, including carbon paste, modified carbon paste inclusion β-cyclodextrin, and carbon nanotubes for the quantification of dorzolamide hydrochloride (DRZ). This study is mainly based on the construction of three different carbon paste sensors by the incorporation of DRZ with phosphotungstic acid (PTA) to form dorzolamide-phosphotungstate (DRZ-PT) as an electroactive material in the presence of the solvent mediator ortho-nitrophenyloctyl ether (o-NPOE). The fabricated conventional carbon paste sensor (sensor I), as well as the other modified carbon paste sensors using β-cyclodextrin (sensor II) and carbon nanotubes (sensor III), have been investigated. The sensors displayed Nernstian responses of 55.4 ± 0.6, 56.4 ± 0.4 and 58.1 ± 0.2 mV·decade−1 over concentration ranges of 1.0 × 10−5–1.0 × 10−2, 1.0 × 10−6–1.0 × 10−2, and 5.0 × 10−8–1.0 × 10−2 mol·L−1 with lower detection limits of 5.0 × 10−6, 5.0 × 10−7, and 2.5 × 10−9 mol·L−1 for sensors I, II, and III, respectively. The critical performance of the developed sensors was checked with respect to the effect of various parameters, including pH, selectivity, response time, linear concentration relationship, lifespan, etc. Method validation was applied according to the international conference on harmonisation of technical requirements for registration of pharmaceuticals for human use ICH guidelines. The developed sensors were employed for the determination of DRZ in its bulk and dosage forms, as well as bio-samples. The observed data were statistically analyzed and compared with those obtained from other published methods.

Highlights

  • Dorzolamide hydrochloride (DRZ) is a treatment of high pressure inside the eye and helps preventing blindness due to glaucoma

  • The literature survey revealed different analytical methods published for the detection of DRZ, such as spectrophotometry [2,3,4,5] and voltammetry [6]

  • Three novel sensors for the determination of DRZ were fabricated by the incorporation of DRZ with phosphotungstic acid to produce DRZ-PT as electroactive material

Read more

Summary

Introduction

Dorzolamide hydrochloride (DRZ) is a treatment of high pressure inside the eye and helps preventing blindness due to glaucoma. The literature survey revealed different analytical methods published for the detection of DRZ, such as spectrophotometry [2,3,4,5] and voltammetry [6]. Other techniques, such as chromatographic separations, were reported for the detection of DRZ in different matrices, including high-performance liquid chromatography [6,7,8,9,10] and thin layer chromatography [11].

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.