Abstract
Selective, sensitive, and reproducible ion-selective electrodes containing dabigatran etexilate- phosphotungstate ion pair as a modifier have been fabricated to determine dabigatran etexilate in pure and pharmaceutical dosage form. The modified electrodes ion selective carbon paste electrode and ion selective pencil graphite electrode showed fast and linear responsewithin a concentration range of 1.0 × 10−5to 1.0 × 10−2 M and 1.0 × 10−6to 1.0 × 10−2 M with a detection limit of 4.36 × 10−6 M and 4.26 × 10−7 M by ISCPE and ISGPE, respectively. Electrodes are selective to dabigatran etexilate over common excipients. The present study demonstrated the determination of dabigatran etexilate in pure and pharmaceutical dosage forms with high accuracy and precision.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.