Abstract

This paper presents two new direct power control (DPC) strategies of three-phase grid connected VSIs for distributed generation, devised for the minimization of common- mode emissions. These strategies have been called DPC-EMC 1 (electro magnetically compatible) and DPC-EMC 2. Both of them reduce the common-mode emissions of the VSI by using either even or odd voltage vectors in each of the six sectors in which the grid voltage lies, without using any null vector. DPC- EMC 2 outperforms DPC-EMC 1 in terms of harmonic content of the injected current and ripple of the active and reactive power waveforms, especially for low DC link voltage/grid voltage ratios. These approaches permit the common-mode emissions to be reduced in comparison with the classic DPC algorithm, at the expense of a slight increase of the harmonic content of the injected current waveform. An experimental comparison among the classic DPC, DPC-EMC 1 and DPC-EMC 2 is presented in terms of dynamic performance, harmonic content of the injected current and harmonic content of the common-mode voltage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.