Abstract

The semi-automated balloon snake active contour (BSAC) based segmentations play a vital role in determining the intima-media thickness (IMT) for accessing the risk related to cardio vascular diseases (CVD). However, the speckle and clutter noise in the ultrasound B-mode images are known to interfere with the contour formation during segmentation. Both noise sources act as false external energy in BSAC and thus influence the resulting boundary definition. A large number of iterations are required for the BSAC to accurately detect the boundary and in the presence of high noise the segmentation algorithm can result in false detections. Thus in this work we have applied the new denoising unsharp masking (UM) method on human common carotid artery in order to reduce clutter noise in the B-mode image before the segmentation process takes place for faster and accurate IMT measurement. The resuts show the number of iterations needed for BSAC to settle on the final intima-media border is less with UM-DAS (100 iterations) compared to that without the denoising technique, DAS (200 iterations). Thus the proposed UM techniques is able to provide better results with less time in measuring the IMT compared to that using DAS.

Highlights

  • The measurement of intima-media thickness (IMT) on common carotid artery is a common clinical practice which has been used to determine the extent of plaque buildup on the walls of the arteries [1], [2]

  • There is a 57.8% increment in IMTmean. This shows that the balloon snake active contour (BSAC) internal contour keeps deforming and has not reached the final minimum energy yet

  • The number of iterations needed for BSAC to settle on the final border is less with unsharp masking (UM) (100 iterations) compared to that without the denoising technique

Read more

Summary

Introduction

The measurement of IMT on common carotid artery is a common clinical practice which has been used to determine the extent of plaque buildup on the walls of the arteries [1], [2]. This clinical procedure has been used by the physicians to assess risk factors or as an earlier indicator of cardiovascular diseases (CVDs) such as heart attack and stroke. This is because there is a strong link between the IMT and cardiovascular events. Ultrasound B-mode imaging has been used widely to estimate the IMT due to its simplicity and non-invasive nature [3]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.