Abstract
In this paper, simplified equations were derived about relation between the commutation surge voltageand key factors of Current Source type Inverter (CSI). And the new commutation method is proposed. The new method is verified by calculations and real test. The new method can decrease the commutation surge voltage smaller half than conventional method.And error between data calculated with equations derived in this paper and results of real test is smaller than 5%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.