Abstract

Ideal fluid management during surgery still poses a clinical dilemma gauging the benefits and adverse effects. This randomized controlled trial compared the tissue perfusion and coagulation profiles under clinically equivalent hydroxyethyl starch (HES 130/0.4) and lactated Ringer's solution (LR). Eighty-four patients undergoing major abdominal surgery were randomized to receive either HES or LR. Tissue perfusion parameters using heart rate, arterial blood pressure, central venous pressure, cardiac index, stroke volume index, and central venous oxygen saturation were measured at T0 (baseline), T1 (start of surgery), T2 (1 hour after start of surgery), and T3 (end of surgery). Coagulation parameters using thrombelastography (TEG) were measured at T0 (baseline), T4 (after 15mL/kg fluid transfused), and T5 (24 hours after baseline). The total amount of fluid administrated was 1547.9±424.0mL in HES group and 2303.1±1033.7mL in LR group (p<0.001). The parameters of tissue perfusion and TEG did not differ significantly between groups at any time point except for a transient decrease in clot kinetic and clot strength at T4 for HES group. There was no significant difference in blood loss and consumption of blood products between the two fluids. HES 130/0.4 is a more efficient intravascular volume expander to maintain tissue perfusion than conventional crystalloid. Transient hypocoagulability induced by HES 130/0.4 does not warrant excessive blood loss and blood transfusion.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call