Abstract

The neutron life time τ n was measured by storage of ultracold neutrons (UCN) in a material bottle covered with Fomblin oil. The inelastically scattered neutrons were detected by surrounding neutron counters monitoring the UCN losses due to upscattering at the bottle walls. Comparing traps with different surface to volume ratios the free neutron life time was deduced. Consistent results for different bottle temperatures yielded τ n sec =885.4±0.9 stat ±0.4 syst .

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.