Abstract

Monte Carlo neutronics calculations have been carried out to compare the effects of chamber ports on the neutron leakage and blanket performance for lithium and lead-lithium blankets. A spherical chamber with diametrically opposed, conical penetrations through the blanket and a 14.1-MeV point source at its center is the basis for the comparison. The total neutron leakage through ports in a lithium blanket is about two times greater than one would estimate based on the solid angle fraction subtended by the holes. For a blanket comprised primarily of the lead-lithium eutectic, PB/sub 83/ LI/sub 17/, the leakage per deuterium-tritium neutron is about six times the subtended solid angle fraction. As a result of the enhanced neutron leakage, the tritium-breeding ratio and neutron energy deposited in the blanket decrease more rapidly than the loss of blanket coverage. For example, for a chamber in which the ports subtend 5% of the total solid angle, the tritiumbreeding ratios are about8 and about20% less than the results without ports for the lithium and PB/sub 83/ LI/sub 17/.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.