Abstract

A set of fluence-to-effective-dose conversion coefficients has been calculated for neutrons with energies <20 MeV using a high-resolution anthropomorphic phantom (Zubal model) and the MCNPX code. The calculation used 13 monodirectional monoenergetic neutron beams in the energy range 10(-9) to 20 MeV, under three different source irradiation configurations: anterior-posterior, posterior-anterior and left lateral. Dose calculations were performed for 18 selected organs of the body, for which the International Commission on Radiological Protection and the International Commission on Radiological Units and Measurements have set tissue weighting factors for the determination of the effective dose. Another set of neutron-fluence-to-effective-dose conversion coefficients was also calculated with the proposed modification wR from ICRP Publication 92. From comparison between the dose results calculated and the data reported for the MIRD and VIPMAN models, it can be concluded that, although some discrepancies exist between the Zubal model and the two other models, there is good agreement in the left lateral irradiation geometry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.