Abstract

In this study the Panasonic UD-802 dosimeter was evaluated as a potential neutron dosimeter for use in the containment of a pressurized water reactor by comparing the results from the UD-802 with remmeter readings. The Panasonic UD-802 dosimeter is used routinely as a beta and gamma dosimeter but due to the natural Li and B in the thermoluminescent materials, it is also sensitive to neutrons. Since a dosimeter's response to neutrons is energy-dependent, proper calibration of the UD-802 in the environment for which it is to be used was an important consideration of the study. To calibrate the system, UD-802 dosimeters were mounted on polyethylene phantoms and irradiated to reference doses at selected locations in containment. The reference doses were determined based on remmeter dose-rate measurements and stay times. The thermoluminescent response of the dosimeters and the reference measurements were used to obtain a response ratio at each location. The average response ratio (unit of dosimeter response per millirem) was 3.7 and all response ratios were within +/-30% of this mean value. Specific characteristics of the UD-802 were also investigated, that is, the effects that dosimeter distance from the phantom and a person's movement through containment have on response. The dosimeter distance from the phantom was found to have a minimal effect on response, but the system was found to be dependent upon the angle of the phantom relative to the reactor core, necessitating a correction in the calibration factor. The overall conclusion of this study was that the Panasonic UD-802 dosimeter can be used for neutron dosimetry in containment of a pressurized water reactor.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call