Abstract

Abstract A technique is described for the measurement of the residual stress tensor averaged over a specified volume within a component. The method involves measurement of small changes in lattice spacing using high resolution neutron diffraction. The stress is inferred from these measurements of the strain, and the theory of the relationship between the two quantities is described, including the effects of crystalline anisotropy. The various types of high resolution neutron diffractometer suitable for the work are described. Experimental results validating the method are given for a simple bent bar of mild steel of known strain, a plastically strained mild steel bar, and a mild steel tube of known torsional strain. Examples of the method in practical use are given by a cracked fatigue test specimen, a double-V test weld and a weld joining a tube to a plate. A more detailed example is the anisotropic response of a polycrystalline sample under elastic and plastic strain; this is illustrated by measurements on many different Bragg reflections from a plastically strained mild steel bar.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.