Abstract

This paper presents the results of neutron diffraction investigations of the residual stress state around a zirconium-stainless steel interface in a bimetallic adapter used for some channels in RBMK-type reactors. The adapter consists of a cylinder with a complex cross section with an outer stainless steel layer and an inner zirconium layer. The experiments are carried out on a Pulse overlap time-of-flight diffractometer (POLDI, SINQ) (Paul Scherrer Institut, Switzerland), a Fourier stress diffractometer (FSD), and high resolution Fourier diffractometer (HRFD) at the IBR-2 pulsed reactor (Frank Laboratory of Neutron Physics, JINR, Dubna, Russia).