Abstract

The FN-II Dense Plasma Focus is a small (< 5kJ ) Mather type device, where the dependence of neutron yield and its anisotropy, in terms of deuterium filling pressure, and the neutron emission angular distribution have been studied. Two diferent electrode configurations have been tested, showing that their geometry plays an important role both on neutron yield and anisotropy. Time integrated anisotropy has been measured with silver activation counters, on a shot to shot basis. CR-39 nuclear track detectors are used to determine the angular distribution of neutrons, averaged over tens of shots, showing that an isotropic pedestal accounts for 70% of the emission, while the anisotropy component accounts for the remaining 30%. The neutron yield shows a tendency to increase with anisotropy, as well as with the emission of hard X-rays observed on-axis. Scintillator- photomultiplier detectors show a slight Doppler shift in the neutron energy at backward angles, supporting the beam-target mechanism. Additional information has been obtained from time inte- grated X-ray diagnostics, which include filtered multi-pin-hole cameras.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.