Abstract

The neutron fields in the collimators of a new design for the vertical neutron camera (VNC) of the ITER have been calculated for a standard isotropic bulk DT neutron source. The neutron and gamma-ray spectra and flux densities at the neutron detector sites have been calculated. The signal-to-background ratio of VNC detectors (238U-based fission chambers and diamond detectors) has been estimated. The signal-to-background ratios versus the threshold energy were calculated for the diamond detectors operating in the threshold counter mode. The effect of background Γ-ray radiation on the performance of the diamond detectors in the VNC environment has been estimated. The radiation heating of the VNC structural components has been calculated. The serviceability of the VNC with the proposed design has been demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call