Abstract

The feasibility of 147Pm and 3H beta-ray sources as static eliminator was experimentally investigated. A sheet of vinyl chloride of 0.1 mm in thickness was used as an example of electrified materials. Its surface charge densities before and after beta-ray neutralization were measured as the function of electrostatic charge changing the speed of the sheet and the distance between the beta-ray source and the sheet. With a 147Pm beta-ray source of 200mCi in effective activity, almost complete neutralization was found for the sheet with the charge density less than 6 X 10(-6) C/m2 running at the speed of 0.18 m/s. In the case of the running speed of 0.5 m/s frequently used in industry, the electrostatic charge below 3 X 10(6) C/m2, where corona discharger is not so effective, was also perfectly eliminated. It was found that the optimal distance between the beta-ray source and the sheet was 10 cm in the case of 147Pm. The use of 3H beta-ray source of 1 Ci was not satisfactory. These results demonstrate that 147 Pm beta-ray source operates most efficiently as static eliminator when the charge density of material and/or its moving speed is not high.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.