Abstract

We present an assessment of the (6s2) (1)S0 ↔ (6s6p)(3)P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly 3 orders of magnitude and demonstrate an atomic quality factor Q of ∼10(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697±0.0011 nm and at a lattice depth of 20E(R). The atoms are loaded from a single-stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. We find the frequency of the clock transition to be 1,128,575,290,808,162.0±6.4(syst)±0.3(stat) Hz (i.e., with fractional uncertainty=5.7×10(-15)). Neither an atom number nor second order Zeeman dependence has yet been detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing, and detection.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call