Abstract

Somatosensory evoked magnetic fields (SEFs), corresponding with electrical median nerve stimulation, were measured using an MRI-linked, whole-head MEG system. In total 184 hemispheres, SEFs were measured, involving 22 normal volunteers and 70 patients with intracranial lesions. The first SEF peak appeared 20.2 ± 1.5 msec (mean ± S.D.) after stimulation. The first peak was followed by a second and third peak, 7.7 ± 3.2 msec and 14.6 ± 5.4 msec respectively after the first. Corresponding isofield maps suggested a single current dipole oriented in the anterior direction for the first peak, posterior for the second and either anterior or posterior for the third. Using a spherical model and a single current dipole source, the localization of each peak was estimated and superimposed on individually determined MRI images. On a grand average basis, the first-peak dipole was localized on the posterior surface of the central sulcus, “area 3b.”. The second-peak dipole was localized 3.7 mm medial ( P < 0.001) and 2.0 mm superior ( P < 0.001) to the first-peak dipole, on the anterior wall of the central sulcus, “area 4”. This study with a large number of subjects was able to statistically distinguish two adjacent cortical sources, located on opposite walls of the central sulcus, and within a few millimeters of each other.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call