Abstract

Delayed in-stent stenosis is an important and well-characterized complication of angioplasty and stenting for the treatment of intra- and extracranial atheromatous disease. The current series describes the incidence and natural history of in-stent stenosis after the deployment of the Neuroform stent within the cerebrovasculature for the treatment of aneurysms. The collaborative Cleveland Clinic Foundation-Barrow Neurological Institute endovascular database was reviewed to identify cases of delayed moderate or severe in-stent stenosis observed during the follow-up of cerebral aneurysms treated with the Neuroform stent. The hospital charts, clinic records, and operative reports for these patients were reviewed. Of a total of 156 patients with follow-up, nine (5.8%) cases of moderate or severe delayed (>2 mo) in-stent stenosis were identified, including two parent vessel occlusions. In two cases, patients presented 3 months after stent-supported aneurysm embolization with focal neurological symptoms. Both of these patients were treated with angioplasty. One eventually required surgical bypass. Of the seven asymptomatic patients, four demonstrated some degree of spontaneous resolution at follow-up, one progressed to complete occlusion, one is awaiting further follow-up, and one patient died of unrelated causes. Of the nine patients in the series, five were treated with "bioactive" coils (Matrix, Hydrocoil, Cerecyte), three were treated with bare platinum coils, and one was treated with stenting alone. The earliest time interval to diagnosis was 2.5 months and 3 months for asymptomatic and symptomatic patients, respectively. The earliest interval documented for spontaneous resolution was 9 months. Delayed Neuroform in-stent stenosis, occurring in 5.8% of cases, is not a rare phenomenon. The stenosis can be symptomatic and may require endovascular treatment or surgical bypass. In asymptomatic patients, a strategy of "watchful waiting" may be effective because many patients demonstrate partial or complete resolution at follow-up. The spontaneous resolution of delayed in-stent stenosis has not been previously described. This may be a phenomenon unique to the application of low radial force, self-expanding stents within the nonatheromatous cerebrovasculature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.