Abstract

The paper investigates the detection and location of IGBT open-circuit faults in two-level inverter fed induction motor controlled by indirect vector control strategy. The investigation proposes two new approaches entirely based on the Artificial Neural Network (ANN) for the extraction of the exact fault angle corresponding to the IGBT switch open-circuit fault. The first approach (Approach1) based on the Clark currents transform calculates the average value of the Clark currents to find the exact fault angle θ. The second approach (Approach2) based directly on the three-phase stator currents (without any transformation) calculates the average value of the three-phase currents to determine the exact fault angle between the phases (θab, θbc, θca). The paper conducts also a comparative study between the two approaches to assess the merits of each one of them. Experimental work is conducted to illustrate the effectiveness of the techniques and validate the results obtained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.