Abstract

AbstractBackgroundThe Network Failure Quotient (NFQ) metric summarizes functional MRI network integrity. We wanted to investigate the stability of the NFQ results across time, hardware, software and protocol changes during the last decade in ADNI Resting State (RS‐) fMRI.MethodIn ADNI‐2 (2009‐2016) RS‐fMRI was acquired on Philips scanners. In ADNI‐3 (2017‐present) RS‐fMRI is acquired on GE, Philips, and Siemens systems with “Basic” and “Advanced” variants based on the availability of simultaneous multi‐slice (SMS, multi‐band) imaging. (Table 1.) Resting state images were preprocessed by performing slice timing correction, trimming volumes from the first 10 seconds of acquired data, despiking and within‐series alignment. Simultaneous bandpass and regression was performed using spatial registration parameters and their first temporal derivatives, mean WM signal, mean CSF signal and global signal. Dual regression via GIFT was applied creating regional time courses. The NFQ is calculated as NFQ=(pDMN_to_vDMN + pDMN_to_adDMN) / (pDMN +vDMN) where pDMN_to_vDMN and pDMN_to_adDMN are correlations between time courses in the posterior DMN, ventral DMN and anterior‐dorsal DMN. pDMN and vDMN are the within‐region correlations. NFQ values from 1447 scans of 739 individual study participants (Table 1) were analyzed using linear mixed effects models to account for age, clinical diagnosis, vendor, and time trends.ResultBox plots of NFQ values by diagnosis within ADNI‐phase and protocol are shown in Figure 2 and suggest important differences among clinical diagnoses and between ADNI‐2 and ADNI‐3. The mixed model analysis indicates that a 10‐year increase in age is associated with a 0.05±0.01 (mean±SD) increase in NFQ; individuals with MCI average roughly 0.05±0.01 higher than unimpaired and individuals with dementia average 0.14±0.02 higher. Differences by vendor for ADNI‐2 and ADNI‐3 are summarized in Figures 2 and 3 with effect sizes on par with these clinical factors. Mean NFQ for Phillips ADNI‐2 were highest (0.54±0.02); somewhat lower were Philips ADNI‐3 (0.51±0.02) and Siemens ADNI‐3 advanced (0.49±0.03); Siemens ADNI‐3 basic (0.40±0.02) and GE ADNI‐3 were the lowest (0.38±0.02).ConclusionNFQ values consistently increase with impairment. Vendor‐specific differences are observed and vendor changes over the life of a study introduce variability on the scale of disease‐related changes in NFQ.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.