Abstract
An inflatable miniature cuff was used to apply local compression of 80 mm Hg or 30 mm Hg to a segment of rat sciatic nerve for time periods varying from two to eight hours. The endoneurial fluid pressure was measured by direct micropipette measurement techniques at one or 24 hours after removal of the cuff, and the nerves were subjected to histological analysis. Endoneurial oedema, associated with a four-fold increase in endoneurial fluid pressure, was observed after compression at 80 mm Hg for four hours, and a three-fold increase was found after compression at 30 or 80 mm Hg for eight hours. Such an increase in endoneurial fluid pressure may interfere with intrafascicular capillary flow, and thereby constitute an important pathophysiological mechanism in nerve compression injuries.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Neurology, Neurosurgery & Psychiatry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.