Abstract

Neonatal screening for congenital hypothyroidism was introduced in the City of Birmingham in 1980 by measuring concentrations of both thyroid stimulating hormone and thyroxine in plasma. Over two years 30 108 babies were tested. Thirty one babies were recalled because of thyroid stimulating hormone concentrations greater than 40 mU/l, of whom 12 were treated with replacement thyroxine. Six babies were found to have low thyroxine concentrations because of reduced thyroxine binding globulin and five raised thyroxine values because of increased thyroxine binding globulin. As a result of this study screening was continued with measurement of thyroid stimulating hormone only as the primary test for congenital hypothyroidism, the thyroxine value being measured only when the concentration of thyroid stimulating hormone exceeded 20 mU/l.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.