Abstract

Negative-silver-ion implantation into tissue-culture polystyrene (TCPS) dishes was investigated and it was found to modify hydrophilic and cell attachment properties of the dishes. Negative-ion implantation has an advantage of being almost free of surface charging, and is a suitable method for implantation into insulators such as polymers. Negative silver ions are used due to the antibacterial property of silver. Ag-implanted TCPS dishes had a contact angle larger than the normal value of 66° of unimplanted dishes. The contact angle of water had a strong dependence on the ion energy rather than the dose. As a cell-culture experiment, human umbilical vascular endothelial cell (HUVEC) was used in unimplanted and Ag-implanted TCPS dishes, the implantation removed the cell-attachment property of the surface. In implantation with a mask with a striped pattern, most attached cells of HUVEC were in the unimplanted region aligned along a stripe direction.