Abstract

The analysis of solid-state cavity masers is extended to include the reactive component of the paramagnetic resonance. This reactance is inverted (in opposition to Foster's reactance theorem). A two-cavity network makes use of this negative frequency dependence of reactance to obtain a broad-band flat-topped amplifier response. In verification of this theory a ruby maser has been built which has a 95-Mc bandwidth at 14-db gain and operates at 9000 Mc and 1.5°K. This performance is comparable to that of published, tapered magnetic field traveling-wave masers. General network limitations on cavity maser amplifiers are derived. Broadbanding techniques that have been published for parametric amplifiers are essentially equivalent. The tuning of the broad-band amplifier is critical. The same performance can be achieved in a unilateral transmission maser by using circularly polarized cavities, but the problem of circuit design and tuning with the increased number of parameters has thus far prevented successful operation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.