Abstract

The characteristics of the negative cloud-to-ground lightning flashes in Malaysia are studied by analyzing the electric fields generated by the whole flash in nanosecond resolution. A total of 405 strokes obtained from 100 successive negative cloud-to-ground lightning flashes were analyzed, which were recorded from seven convective thunderstorms during the southwest monsoon period, i.e. from April to June 2009. It was found that the total number of interstroke intervals has an arithmetic mean value of 86ms, a geometric mean value of 67ms and does not depend on the return stroke order. Of the 100 negative ground flashes, 38 flashes (38%) have at least one subsequent return-stroke (SRS) whose electric field peak was greater than that of the first return-stroke (RS). Furthermore, 58 (19%) out of 305 SRS have electric field peak larger than those of the first RS. The arithmetic and geometric mean ratio between the peak electric field of the SRS and the peak electric field of the first RS are 0.7 and 0.6, respectively. The percentage of single-stroke flashes was 16% while the mean number of strokes per flash and maximum number of stroke per flash were 4 and 14, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.