Abstract

PurposeAxillary arterial cannulation for blood pressure monitoring has been reported in adults since 1973. Reported failure rates using palpation landmarks are high. This report describes a needle-guided ultrasound technique for axillary arterial line placement in critically ill patients. MethodsA retrospective review of all patients requiring axillary arterial cannulation attempts with ultrasound-assisted needle guidance for hemodynamic monitoring was performed from July 2010 to June 2016 at a single institution. ResultsOne hundred fifty nine (159) cannulation attempts were performed in 155 patients. The overall success rate was 97%, with a first pass success rate of 84%. Inexperienced operators performed 49% of procedures under direct faculty supervision, and had a 99% success rate, which was not different from experienced operators. Almost 20% of patients had moderate-to-severe coagulopathy (platelets<50k/uL, INR>2.0 or PTT>60s). Complications reported included the following: nonfunctioning of catheter (6%) and hematoma (6%). Ischemia was noted in 2 patients (1%), but only one was attributed to the arterial catheter. ConclusionsUse of the needle-guided ultrasound assisted approach for axillary arterial line placement is easily teachable and can be used to promote safe and successful placement of axillary arterial lines for novice learners.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.