Abstract

Introduction Intravenous dexmedetomidine is known to cause major adverse effects such as bradycardia, hypotension, cardiac arrhythmias, and heart block when used as premedication for attenuation of the laryngoscopy and intubation response, limiting its routine use. Thus, it is important to study other routes of administration of dexmedetomidine. Objectives To compare the hemodynamic response and sedation score between intravenous and nebulized dexmedetomidine as premedication for the attenuation of the laryngoscopy and intubation response. Materials and methods In this study, 60 patients fulfilling inclusion criteria undergoing surgeries under general anesthesia (ASA Grade I and II) were randomly allocated into two groups of 30 patients each. Group IV received intravenous 1 mcg/kg dexmedetomidine in 100 mLnormal saline, and Group IN received nebulization with 1 mcg/kg dexmedetomidine diluted to a total volume of 5 cc of normal saline, 30 minutes prior to the induction of general anesthesia. Sedation scores were calculated using the Ramsay sedation score at 20 minutes after the administration of the drug; patients were induced by the standard protocol, and laryngoscopy was performed. Vitals were recorded before the administration of the drug and after intubation at stipulated time intervals. Results The median heart rate becomes significantly lower at 15 minutes (70 vs. 76.5) and 20 minutes (66 vs. 76) after induction among Group IV as compared to Group IN. The median systolic blood pressure was significantly lower at 20 minutes in Group IV (110 mmHg) than in Group IN (119 mmHg). The median diastolic blood pressure was significantly lower at 10 minutes (76 vs. 79), 15 minutes (70 vs. 77), and 20 minutes (69 vs. 78.5) in Group IV than in Group IN. The median of mean arterial pressure was significantly lower at 15 minutes (84.8 vs. 91.5) and 20 minutes (83 vs. 92) in Group IV than in Group IN. A comparison of vitals after induction shows that the median heart rate, systolic blood pressure, diastolic blood pressure, and mean arterial pressure were significantly lower statistically among Group IV as compared to Group IN at 0, 1, 3, 5, 10, 15, and 30 minutes after induction (except for systolic blood pressure at 3 minutes). The median sedation score was lower in Group IN (0) than in Group IV (1); this difference is statistically significant. Conclusion The obtundation of hemodynamic responses following laryngoscopy and maintaining hemodynamics intraoperatively is statistically better with nebulized dexmedetomidine compared to intravenous dexmedetomidine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.