Abstract

Occurrence of large earthquakes close to cities in California is inevitable. The resulting ground shaking will subject buildings in the near-source region to large, rapid displacement pulses which are not represented in design codes. The simulated Mw7.0 earthquake on a blind-thrust fault used in this study produces peak ground displacement and velocity of 200 cm and 180 cm/sec, respectively. Over an area of several hundred square kilometers in the near-source region, flexible frame and base-isolated buildings would experience severe nonlinear behavior including the possibility of collapse at some locations. The susceptibility of welded connections to fracture significantly increases the collapse potential of steel-frame buildings under strong ground motions of the type resulting from the Mw7.0 simulation. Because collapse of a building depends on many factors which are poorly understood, the results presented here regarding collapse should be interpreted carefully.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.