Abstract

BackgroundChyle leaks following oesophagectomy are a frustrating complication of surgery with considerable morbidity. The use of near infra-red (NIR) fluorescence in surgery is an emerging technology and the use of fluorescence to identify the thoracic duct has been demonstrated in animal work and early human case reports. This study evaluated the use mesenteric and enteral administration of indocyanine green (ICG) in humans to identify the thoracic duct during oesophagectomy.MethodsPatients undergoing oesophagectomy were recruited to the study. Administration of ICG via an enteral route or mesenteric injection was evaluated. Fluorescence was assessed using a NIR fluorescence enabled laparoscope system with a visual scoring system and signal to background ratios. Visualisation of the thoracic duct under white light and NIR fluorescence was compared as well as any identification of active chyle leak. Patients were followed up post-operatively for adverse events and chyle leak.Results20 patients received ICG and were included in the study. The enteral route failed to fluoresce the thoracic duct. Mesenteric injection (17 patients) identified the thoracic duct under fluorescence prior to white light in 70% of patients with a mean signal to background ratio of 5.35. In 6 participants, a possible active chyle leak was identified under fluorescence with 4 showing active chyle leak from what was identified as the thoracic duct.ConclusionThis study demonstrates that ICG administration via mesenteric injection can highlight the thoracic duct during oesophagectomy and may be a potential technology to reduce chyle leak following surgery.Clinical trial registrationClinical trials.gov (NCT03292757).

Highlights

  • Chyle leaks following oesophagectomy are a frustrating complication of surgery with considerable morbidity

  • This study was an IDEAL [12] 1/2a open label prospective proof of principle study assessing indocyanine green (ICG) to fluoresce the thoracic duct during oesophagectomy conducted in a single tertiary referral centre

  • ICG was given in the operating room following induction of anaesthesia and fluorescence was assessed using a commercially available fluorescence enabled laparoscope compatible with ICG (PINPOINT or Stryker)

Read more

Summary

Introduction

Chyle leaks following oesophagectomy are a frustrating complication of surgery with considerable morbidity. This study evaluated the use mesenteric and enteral administration of indocyanine green (ICG) in humans to identify the thoracic duct during oesophagectomy. Administration of ICG via an enteral route or mesenteric injection was evaluated. Visualisation of the thoracic duct under white light and NIR fluorescence was compared as well as any identification of active chyle leak. Patients were followed up post-operatively for adverse events and chyle leak. Mesenteric injection (17 patients) identified the thoracic duct under fluorescence prior to white light in 70% of patients with a mean signal to background ratio of 5.35. Conclusion This study demonstrates that ICG administration via mesenteric injection can highlight the thoracic duct during oesophagectomy and may be a potential technology to reduce chyle leak following surgery.

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call