Abstract

ABSTRACT In a bid to simultaneously exploit the advantages of Pulsed Eddy Current testing (PEC) and Pulsed Remote-field Eddy Current Testing (PRFEC) for evaluation of buried defects in layered conductors, in this paper the Near- and Remote-field Pulsed Eddy Current integrated testing (NRPEC) alongside an axi-symmetric probe has been proposed. Simulations are conducted to reveal the field characteristics underlying the proposed method and analyse the signal response to hidden flaws. In parallel, an NRPEC system has been built up. Based on the images of near-field and remote-field signal features, a fusion algorithm is proposed to fuse the signal features of near-field and remote-field signals for defect testing with the enhanced signal-to-noise ratio. Results from simulations and experiments indicate that based on the fused signal feature, high-accuracy imaging of hidden defects in a double-layer conductor can be achieved via NRPEC with the improved signal-to-noise ratio.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.