Abstract

Flash point is the most important property that characterize the explosion and fire hazard of liquid mixture. In this paper, flash points of ternary liquid mixture, which is n-decane+n-undecane+n-tridecane system, were measured with Seta flash tester. Measured values were compared with calculated values through Raoult’s law and multiple regression analysis. Absolute average error of the result calculated by Raoult’s law is 1.2 ℃. Absolute average error of the result calculated by multiple regression analysis is 1.0 ℃. As can be seen from absolute average error, the values calculated through multiple regression analysis are more effective than those calculated according to Raoult’s law.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.