Abstract

The killing effect of pulsed electric fields (PEF) on Escherichia coli (ATCC 8739) suspended in an orange juice and milk beverage was studied. Bipolar square pulses with a pulse width of 2.5 μs were applied. Electric field strength and treatment times ranged from 15 to 40 kV/cm, and from 0 to 700 μs, respectively. A maximum of 3.83 log reductions was achieved at 15 kV/cm and 700 μs. The experimental data were fitted to Bigelow and Hulsheger models and Weibull distribution function. Results indicated that Weibull function best described the experimental data (lowest mean square error). As there were no significant differences in the values of the shape factor (n) at the electric field strength of 25–40 kV/cm, the number of parameters in the Weibull model were reduced, leading to a simplified model with a fit similar to that obtained with the full model.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.