Abstract
BackgroundAs new heart rhythm monitoring technologies emerge, subclinical atrial fibrillation (AF) signifies a future challenge to health care systems. The pathological characteristics of this condition are largely unknown. ObjectivesThis study sought to characterize the natural history of subclinical AF in at-risk patients from the general population. MethodsThe authors studied 590 individuals ≥70 years of age with ≥1 of hypertension, diabetes, previous stroke, or heart failure, without history of AF, undergoing long-term implantable loop recorder monitoring as part of the LOOP (Atrial Fibrillation Detected by Continuous ECG Monitoring Using Implantable Loop Recorder to Prevent Stroke in High-risk Individuals) study. Baseline assessments included N-terminal pro–B-type natriuretic peptide (NT-proBNP). All day-to-day heart rhythm and symptom data were extracted from the device. Endpoints included AF burden, AF progression, symptom reports, and heart rate during AF. ResultsA total of 685,445 monitoring days were available for analysis. Adjudicated AF episodes lasting ≥6 min were detected in 205 participants (35%). The AF burden was median 0.13% (interquartile range: 0.03% to 1.05%) of the monitoring time and changed by a factor of 1.31 (95% CI: 1.02 to 1.68) per doubling of NT-proBNP. AF episodes were present 2.7% (interquartile range: 1.0% to 15.7%) of monitoring days after debut. Progression to 24-h episodes was seen in 33 of the AF patients (16%), whereas 46 (22%) had no AF episodes in the last 6 months of monitoring or longer. Symptoms were absent in 185 (90%) at debut, and 178 (87%) never reported AF-related symptoms during follow-up. The averaged heart rate during AF was 96 (interquartile range: 83 to 114) beats/min, 24 (interquartile range: 9 to 41) beats/min faster than daytime sinus rates. ConclusionsAlthough previously unknown AF was highly prevalent, the burden was low, and progression was limited. In addition, symptoms were scarce, and the heart rate was only modestly elevated. (Atrial Fibrillation Detected by Continuous ECG Monitoring Using Implantable Loop Recorder to Prevent Stroke in High-risk Individuals [LOOP]; NCT02036450)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.