Abstract

Simple and green natural deep eutectic solvent (NADES) based ultrasound assisted liquid-liquid micro-extraction (UA-LLME) method was developed for extraction and determination of methyl violet dye in contaminated river water samples using UV/Vis spectrophotometry. Choline chloride - decanoic acid based natural deep eutectic solvent was used for extraction. Important analytical parameters like pH, deep eutectic solvent volume/phase ratio, tetrahydrofuran volume, sonication time, and temperature were optimized. Limit of detection (LOD) and limit of quantification (LOQ) were 2.20 μg/L and 7.34 μg/L respectively. Relative standard deviation was 2.35–3.21%. Linearity of method was investigated in a concentration range 10–400 μg/L. Enrichment factor was calculated as 20. For 20 mL sample, the optimized parameters were as deep eutectic solvent volume 1.5 mL, tetrahydrofuran volume was 0.6 mL, pH = 6, sonication time 2 min. The optimized method was tested for extraction of methyl violet in real water samples confirming its applicability in routine environmental analysis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call