This study aims to investigate the effects of the unhealed entry or unheated exit section on the free convection heat transfer in airflow in vertical parallel plate channels resulting from the thermal boundary conditions of uniform heat flux (VHF) and uniform wall temperature (UWT). Results of average Nusselt number and dimensionless volume flow rate are presented in terms of the ratio of the length of heated section to the full channel length and a Rayleigh number, ranging from the limit for the fully developed flow to that for single-plate behavior. Analytical equations for dimensionless volume flow rate and average Nusselt number for both unheated restrictions and both thermal boundary conditions have been developed for the fully developed flow limit. The numerical solutions are shown to approach asymptotically the approximate solution for fully developed flow as the Rayleigh number approaches 1 or less. An important finding of the study is that an unheated exit characterizes greater total heat transfe...