Abstract
In this article, we numerically study natural convection heat transfer in a cylindrical annular cavity with discrete heat sources on the inner wall, whereas the outer wall is isothermally cooled at a lower temperature, and the top wall, the bottom wall, and unheated portions of the inner wall are assumed to be thermally insulated. To investigate the effect of discrete heating on the natural convection heat transfer, at most two heating sources located near the top and bottom walls are considered, and the size and location of these discrete heaters are varied in the enclosure. The governing equations are solved numerically by an implicit finite difference method. The effect of heater placements, heater lengths, aspect ratio, radii ratio, and modified Rayleigh number on the flow and heat transfer in the annuli are analyzed. Our numerical results show that when the size of the heater is smaller, the heat transfer rates are higher. We also found that the heat transfer in the annular cavity increases with radii ratio and modified Rayleigh number, and can be enhanced by placing a heater with the smaller length near the bottom surface.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.