Abstract

Inhalation toxicity studies of nanoparticles require production of test aerosols with a number of acceptable characteristics. Five different generation methods for producing a nanoparticle aerosol from the bulk powder were evaluated with the goal of producing an acceptable aerosol that is homogenous, has a consistent concentration over time in which the magnitude may be intentionally varied, and has a size distribution that is both unimodal and has a small geometric mean diameter relative to the primary particle size of the nanoparticle bulk powder. Four types of bulk powders were evaluated including titanium dioxide, silicon dioxide, polymer-coated silver, and single walled carbon nanotubes. A nebulizer was the only tested method able to produce a consistent aerosol of sufficient magnitude. However, the resulting aerosol contains particles derived from the carrier water. Prior sonication of the nanoparticle suspension alone was found to be not useful for deagglomerating nanoparticles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.