Abstract

An easy and fast Fourier transform continuous cyclic voltammetric technique for monitoring of ultra trace amounts of naltrexone in a flow-injection system has been introduced in this work. The potential waveform, consisting of the potential steps for cleaning, stripping and potential ramp, was continuously applied on an Au disk microelectrode (with a 12.5 microm in radius). The proposed detection method has some of advantages, the greatest of which are as follows: first, it is no more necessary to remove oxygen from the analyte solution and second, this is a very fast and appropriate technique for determination of the drug compound in a wide variety of chromatographic analysis methods. The method was linear over the concentration range of 0.34-34000 pg/mL (r = 0.9985) with a limit of detection 8.0 x 10(-4) nM. The method has the requisite accuracy, sensitivity, precision, and selectivity to assay naltrexone in tablets. The influences of pH of eluent, accumulation potential, sweep rate, and accumulation time on the determination of the naltrexone were considered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.