Abstract

The paper demonstrates how to deal with the Near-field Acoustic Holography method (NAH) for reducing noise source which is generated in air-conditioning compressor. Sound radiation was measured for both normal compressor and fault compressor. The acoustic noise holograms are predicted by measuring at discrete multiple points around the two compressors and are thereafter reconstructed on the surface of the compressors. 1344 measuring points are used by two microphones in which one is scanning microphone and the other is reference microphone. NAH is a good tool for the visualization of Sound so we can show the source of sound graphically. In this paper, the NAH method found the exact noise source position on the surface of the compressor and the noise-related sub part in the compressor. We found the NAH and is very useful as a noise reduction tool for home-appliance device.